waste incinerator manufacturers china
5-1- Chambre de post combustion est installée au dessus du foyer de combustion, elle est constituée d’un cylindre métallique revêtu intérieurement d’une couche d’ isolant et d’une couche de matériaux…
HICLOVER| Incinerator|Medical Waste Incinerator|Environmental Incinerator|Pet Animal Incinerator|Medical Incinerator|Incinerator|Incinerator Manufacturer|China Incinerator|Medical Incinerators
5-1- Chambre de post combustion est installée au dessus du foyer de combustion, elle est constituée d’un cylindre métallique revêtu intérieurement d’une couche d’ isolant et d’une couche de matériaux…
Incinerators used will be restricted to daylight hours of operation. This includes shutdown, cleaning and maintenance. Waste streams shall not be mixed during the incineration process and the ash collection…
Equipped with main combustion chamber and a second Room for reburning Made to ensure complete combustion of the gases resulting from incomplete combustion of inert gases in the chimney, within…
The following requirements are to be considered as an essential part of the technical specifications for each equipment type. The system offered shall be made to operate normally under the…
It’s anticipated that the Bidder will cooperate closely with PATH and target Hospitals for the new waste management building/area and will make available all needed technical information, drawings, etc., The…
SECTION V TECHNICAL SPECIFICATIONS OF THE INCINERATOR General Description The plant has to have four different sections that demonstrate three fundamentals of turbulence, residence time and temperature retention. The regulated…
Finally, steam to the coat should shut off, the unloading door is to be opened Then the shaft and mixing arms are reversed to behave as unloading mechanism and should…
Medical waste, disposable syringes, infusion sets processing, cotton yarn, the operating room, the residual limb, waste rubber gloves, protective clothing and infectious and harm venereal hospital bed supplies, general wastes…
Sterilization time: approx. 30 minutes at 121◦C/1.1 Tavern or approx 15 minutes at 132◦C/2.5 Tavern to reach 6log10 sterility Fragmentation within the chamber: Heavy duty with maximum size of final…
Model HICLOVER YD-30C Picture Feed Capacity Average 30-50 kgs per feed Burning Rate Average 30 kgs per hour Voltage 220V Power 0.59Kw Fuel Natural Gas or Diesel oil Burner Italy…
Incinerators to be appropriate for the expert disposal of clinical & & & & medical waste/ rubbish having a better lots capability from the selection of about 1000-1500 Kg. The…
Battery Charger: Must be built in battery charger, rectifier type with transformer, circuit breaker and overload protection plugs into any 220VAC outlet. Steering: A pallet truck style steer handle for…
Items/Model TS1000 Picture Principle Solid Waste Incineration Treatment Burn Rate Average 1000kg/hour Feed Capacity Average 6000kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 4800Liter Internal Dimensions 400*120*100 cm Secondary…
? Opening Doors – the closed and fixation automated system, that are handled remotely by the operator. ? Designed to operate in long mode and quick Action ( Quick Start…
“Waste chamber Chamber capacity 300 kg Chamber quantity .54m3 Chamber dimensions (outside) Width: 91cm, Height: 86cm Length: 152cm Door opening 66 x 76 cm Height to door 84 cm Height…
*Primary combustion chamber *Secondary combustion chamber *Smoke filter chamber * Stainless Steel chimney *Auto PLC control system *Italy brand burner * Automatic Protection Operator(APO) *Heavy duty refractory chamber *Corundum Temperature…
Incinerator Items/Model HICLOVER TS30(PLC) Burn Rate (Average) 30-50 kg/hour Feed Capacity(Average) 60kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 330L Internal Dimensions 75x75x60cm Secondary Chamber 180L Smoke Filter Chamber Yes…
air retention for at least 2 seconds at a temperature of less than 850C, the combustion to be able to achieve the proper effect. ? Must be a two-chamber incinerators,…
Vertical closed furnace combustion chamber incinerator Medical waste, disposable syringes, infusion sets processing, cotton yarn, the operating room, the residual limb, waste rubber gloves, protective clothing and infectious and harm…
Incinerator Items/Model HICLOVER TS30(PLC) HICLOVER TS50(PLC) HICLOVER TS100(PLC) Burn Rate (Average) 30-50 kg/hour 50-100 kg/hour 100-150 kg/hour Feed Capacity(Average) 60kg/feeding 100kg/feeding 350kg/feeding Control Mode PLC Automatic PLC Automatic PLC Automatic…
Dimensions: World standard: 0.83m(I) x 1.0m(w) x 1.4m(h) Burning efficacy: >98% china double chamber incinerator Features: ? Waste type and burn rate: Designed specifically for use by poultry farmers, game-keepers…
Double Combustion Chamber Medical Waste Incinerator Hot Face,High aluminum firebrick 55% of Al203,1750°C Grade. Code face, High Rate Refractory Ceramic Fiber, 1050°C Grade
Number item: 01 unit Can you please send us cataloge detail for Pet Cremation of dogs, cats. – Please services need: General about Cremation system which is appropriate Up to…
18 Electrical supply required 3-phase 19 Auxiliary fuel Diesel or paraffin 20 Main burner 21 Secondary (Later ) burner 22 Kind of burners Automatic pressure jet 23 Output Primary Approx…
INSULATION. Limiting Regular solution limit 1000 amounts C. Waste kind: MEDICAL CARE WASTE Small Capacity: 50Kg/Hour set tons. Thickness 25mm THROUGHPUT. 50kg/hour at a small calorific well worth of 4,000…
Would plant operations be usable on a basis of 24 hours per day, 7 days a week, all year long except for regular and preventative maintenance periods? What volume and…
An operating test ought to be conducted to make certain that each of the control components have been properly installed and that all areas of the incinerator, such as controls…
The successful bidder will deliver the incinerator slide in a container. A containerized alternative is also acceptable. incinerator with a closed air surroundings,
Supervision of installation of the new incinerator set shall be provided by the successful Bidder while labor and heavy duty equipment shall be provided by CEB. ? The successful Bidder…
Flue Gas Cleaning System ? quoted individually ) 7 Chimney Height 10m (minimal ) ? Overall duration of the supervision of installation, testing and commissioning works shall not exceed 2…
Incinerator dual chamber with capacity 1.5 m3/batch or 6 m3/ day, electronic thermocontrol range 0‐1200 C, thermocouple, air supply capacity 10m3/ minute, electricity consumption 1.2kWH/ hour, power 3 phase with…
Incinerate: medical waste and general waste Capacity to burn waste: 400-500kg/hr Fuel: Diesel Gas Consumption: 10 liters/hr maximum Incineration temperature: 950-1300 degrees centigrade Casing: thick (min 5mm) stainless steel casing…
The incinerator fuel tank shall meet the following requirements: a) The tank shall be installed above ground and according to all of the fuel tank requirements in Section 1015 including…
I also research their product information and find it don’t require fuel and also not require fan blower but that incinerator can only burn waste with 30%-40% humid. I don’t…
Medical waste is posing a growing problem all over the world, jeopardizing the health of staff, patients, disposal workers and anyone else coming into contact with the often hazardous materials…
Programming controls. planned method. Appropriate prepurge, ignition, postpurge, and modulation ought to be verified. A stopwatch ought to be used for confirming periods of time. ? The satisfactory operation of…
Fully automatic sequential control provided by internal Secondary chamber pre-heat Burn cycle (variable) Cool down cycle PLC system providing control of: Gas Alternatives Diesel, LPG, Natural or Bio Gas. Average…
Anchor all gear to building floor or construction as shown or as recommended by manufacturer with allowance for thermal expansion as required. Control and Instrument Panel: Rigidly attach enclosure to…
Including:Incinerator: Structure to be specified – A receiving cage for biomedical waste; – A combustion chamber using a chimney using a filter to keep the ashes; Chimney section: about 300…
Test shall be conducted by factory authorized representative of incinerator manufacturer. Demonstrate required weight reduction of specified waste. Waste shall be fed in a single batch to the unit. After…
The incinerator will then take supply from the DO tank through its DO feed pumps to its respective burners. An incorporating meter shall be installed to measure the quantity of…
The successful Bidder shall inform CEB in writing at least three (3) weeks prior to the carrying out of factory tests so as to enable sending of a CEB Engineer…
HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial trends. Containerization enables immediate waste management as the units…
standard type, 11m long,self supporting Capacity-220kgs/hr refuse-hospital waste average moisture-15-20% on fist time DIMENSIONS height: 2710mm span: 2840mm Width; 2450mm loading door opening: 610mm x 610mm Grate/Heath Area: 2.0(square meters)…
A chamber of post combustion of gases * A burner of combustion of gases, * A device of injection of air allowing a total recombustion of gases, * A device…
incinerator. High Temperature Waste Incinerator Model D. MB 750XL Burn Rate-150Kg/hour minimum Weight(Kg)-4000kg Secondary Chamber (double chamber with post-burning) Gas Retention Time 2 second Fuel Diesel Power Supply for control…
Equipment Access Openings: Organize all piping and equipment to allow access to openings without disassembly of piping or equipment. Provide space which permits full opening of all doors, panels, and…
heavy Duty Steel casing High Quality refectory lining & insulation 1 x Diesel fired ignition burners operated on / off Front Loading Door (safety catch Independent Ash Elimination Door 2.7…
Burning Capacity: 125 kg minimum/time (3-6times/day), double chamber, double combustion system Per your advertisement for 300 kg.hr. Model – We will need to know the purchase price via return. How…
The temperature is over the minimum and under the maximum required temperature (e.g 1150? C) of the thermal reactor (partial load). When switching off, only the solenoid valve for the…